PS-3650A / PS-3651A Reference Manual
3-28
3.8 Setup Guide for the System Monitor Property
The System Monitor Property allows you to specify PS-A items you want to monitor with the RAS features
and the notification method used when errors/alerts occur. When an error/alert occurs, notification is provided
according to the method specified in the System Monitor Property.
The following table lists the operating settings that can be configured for each feature.
O: Setting available X: Setting not available
The following table lists the default settings of each feature.
O: Setting X: Not set X: Not applicable
• For procedure to set up the System Monitor Property, refer to the following section.
• You can check the status of the PS-A unit you are monitoring with the RAS features on the
System Monitor screen.
For details regarding the System Monitor screen, refer to the following.
Feature
Operation
Buzzer
Popup
Message
OS
Shutdown
LED
DOUT
0, 1
*2
Reset
Timeout
(sec):
Watchdog Timer O O O O O O O
Voltage O O O O O X X
Fan
*1
*1: Nothing is displayed on PS-3651A.
OO OOOXX
Temperature O O O O O X X
SMART O O X O O X X
DIN0, 1
*2
*2: Nothing is displayed on PS3650A-T42S / PS3651A-T42S.
OO OOOXX
Remote Reset
*2
XX XXXOX
Backlight O O X O O X X
• Administrator Authentication is required for executing SMART Monitoring. When a
user who does not have the administrator authentication logs in, nothing is
displayed in the item of SMART.
Feature
Operation
Buzzer
Popup
Message
OS
Shutdown
LED
DOUT
0, 1
*2
Reset
Timeout
(sec):
Watchdog Timer X O X O X X O (5sec)
Voltage X O X O X - -
Fan
*1
*1: Nothing is displayed on PS-3651A.
XO XOX--
Temperature X O X O X - -
SMART X O - O X - -
DIN0, 1
*2
*2: Nothing is displayed on PS3650A-T42S / PS3651A-T42S.
XO XOX--
Remote Reset
*2
-- ---X-
Backlight X O - O X - -
SEE
3.3.2 Setup Procedure (page3-11)
SEE
3.9 Setup Guide for the System Monitor Screen (page3-34)